APAR Description
PH17508 HIPAA COMPLIANCE CHECK AK901 DOES NOT REPORT "R" WHEN HIPAA_999_ENABLED IS "T"
PH17435 837P DATA SHOULD FAIL WHEN BOTH 2320 AND 2430 AMT*EAF ARE PRESENT
PH17434 837P DATA NOT FAILING WHEN 2320 AMT*A8 CLM02 IS OUT OF BALANCE
PH17432 CLAIMS ARE PASSING COMPLIANCE WHEN BOTH 2320 AMT*D AND 2320 AMT*A8 ARE PRESENT FOR THE SAME PAYER
PH17430 WHEN MULTIPLE OTHER PAYERS ARE ON CLAIM (2320 LOOPS), EDIT IS NOT SEEING WHICH OTHER PAYER IN DTP*573 IS BEING SENT
PH17429 HIPAA 837I 2300 ADMISSION DATE CLAIM LEVEL REJECTION
PH17423 837P TRANSACTIONS WITH A PWK05 BUT NO PWK06 ARE PASSING, SHOULD FAIL, AS PWK SYNTAX REQUIRES BOTH IF ONE OR THE OTHER IS USED
PH17413 837 2010AA REF, BILLING PROVIDER TAX ID REF01 SPECIFIES FORMAT OF HOW TAX ID SHOULD BE SENT, REF02 SHOULD FAIL WITH ALPHA CHAR
PH17408 837I TRANSACTION CORRECTLY FAILS COMPLIANCE FOR SV205 BEING TOO LONG, BUT IS REPORTING ERROR AS SV204 INSTEAD OF SV205
PH17394 COMPLIANCE CHECK DOES NOT REJECT 5010X222A1 837 WHEN BOTH 2320 LOOP AMT*A8 SEGMENT AND 2430 LOOP CAS SEGMENT ARE PRESENT
PH17378 COMPLIANCE CHECK DOES NOT REJECT 5010X222A1 WHEN BOTH 2320 LOOP AMT*A8 SEGMENT AND 2330B LOOP DTP SEGMENT ARE PRESENT
PH17375 COMPLIANCE CHECK DOES NOT REJECT 5010X222A1 837 WHEN BOTH 2320 LOOP AMT*A8 SEGMENT AND 2430 LOOP SVD SEGMENT ARE PRESENT
PH17373 ERROR SEEN IN BOTH 2320 AND 2430 LOOP WHEN CAS03 IS TOO LONG IS ERROR CODE 1 WHEN IT SHOULD BE REPORTING ERROR CODE 5
PH17347 COMPLIANCE CHECK NOT REJECTING 5010X222A1 837 WHEN 2330 PROVIDERLOOP IS PRESENT, BUT THERE'S NO CORRESPONDING 2310 PROVIDER LOOP
PH17298 HIPAA 835 TRANSACTIONS PASSING COMPLIANCE WHEN THEY DO NOT BALANCE - SUM OF LOOP 2110 SVC02 MUST EQUAL LOOP 2100 CLP03
PH16622 HIPAA COMPLIANCE CHECK REPORTS ERROR CODE 4 - DATA ELEMENT TOO SHORT FOR 837 2300 REF02 GREATER THAN 20 CHARACTERS
PH16442 COMPLIANCE CHECK ISSUE WITH MILITARY LOCATION CODES - AA, AE, AND AP - SHOULD BE INCLUDED TYPE 5 CODE LIST 22
PH16251 COMPLIANCE CHECK ISSUE IN VALIDATION OF UM SEGMENT DATA USING 278N HIPAA TYPE 2 TYPE TREE
PH15995 CLAIMS ARE PASSING COMPLIANCE WHEN THE 2320 LOOP CONTAINS THE CAS SEGMENT AND THERE IS NO 2320 AMT*D.
PH15394 HIPAA SEGMENT TYPE TREES CONTAIN INCORRECT COMPONENT RULE FOR THE LOOPIDCD ELEMENT AS $="2310F" INSTEAD OF $="2310E"
PH15389 837P HI FATAL ERROR OCCURS WITH PATCHES APPLIED TO HEALTHCARE PACK 9.0.2, WHEREAS AT BASE (GA) IT FAILS AT THE CLAIM LEVEL
PH15196 IK403 ERROR CODE FOR THE "N402 AND N407 MAY BOTH BE PRESENT" REQUIREMENT SHOULD BE "10 - EXCLUSION CONDITION VIOLATED"
PH15177 820 FALSE BPR COMPLIANCE FAILURES WHEN BPR02 IS 11 CHARACTERS AND DTM IS INCORRECT
PH11478 MISSING CLP05 WHEN CLP02 NOT EQUAL 22 AND CAS SEGMENT EXISTS WITH CAS01 = PR AND CAS03 > 0 IS NOT REJECTED

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSQ9TT","label":"IBM Sterling Transformation Extender Pack for Healthcare"},"Component":"Pack for Healthcare","Platform":[{"code":"PF002","label":"AIX"},{"code":"PF016","label":"Linux"},{"code":"PF033","label":"Windows"},{"code":"PF035","label":"z\/OS"}],"Version":"10.0.2, 10.0.2.0","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]